Overall Solutions For Green Data Center

With the increasing requirements of national policy on energy saving, energy saving is becoming the focus of the country and the whole society. China’s rapid development of information construction and huge demand of information has led to a lot of data center construction. The proportion of IT energy consumption in all the power consumption is rising. The data center has become a veritable “electric tiger” in wide range of industries. Energy saving and reducing consumption of data centers is extremely urgent. To develop the green data center become one of the primary tasks for the development of data center building.

Currently, the data center power consumption accounts for 1% of the global total consumption. In 2010, the power consumption of data centers in the United States reached 100 billion kilowatt, accounting for 2.5% of the total power consumption, and China has reached 2.4%. Resources and environmental problems have become the bottleneck in the development of the data center.

EYP Mission Critical Facilities Consumption Analysis to Room of Data Center

The energy consumption of data center is mainly composed of the following components:

First, IT Equipment System. The power consumed by the server, storage and network communications devices accounts for about 50% of the total power required by the data center room. The servers share about 40% of total power consumption and the other 10% of the power is shared equally by the storage devices and network communications equipment.

Second, Air Conditioning System. The power consumed by the air conditioning system accounts for about 37% of the total power required by the data center room. The air conditioning refrigeration system accounts for about 25% and about 12% of the power consumption is used for power consumption of the air conditioning supply and return air system.

Third, UPS Power Supply System. Their power consumption is about 10% of the total power consumption in the room. About 7% is from the UPS system power consumption and about 3% is from the UPS input power supply system.

Fourth, Lighting System. It accounts for about 3% of the power required by the data center computer room.

According to the analysis of energy consumption, data center energy-saving scheme consists of three levels: First, starting from the critical power and refrigeration, design and implement the scheme on energy saving on the basis of room infrastructure; Second, starting from hardware devices, carry out the energy conservation and reduce IT the energy consumption; Third, starting from chips to conduct energy saving. At present, the energy saving on hardware level and chip level has been recognized by the growing number of users. However, the energy conservation in critical power and refrigeration of infrastructure facilities has not attracted enough attention. In fact, the energy saving of infrastructure is the most important energy-saving way, so that you can solve the energy problem from its source and thus achieve a profound effect in energy saving.

First, increase the energy efficiency of IT equipment and broaden the permissible range of operating temperature and humidity.

If the user selects the IT equipment which are sensitive in working temperature and humidity, it is bound to let them spend a lot of manpower and material resources to establish and maintain energy-consuming air conditioning security system. Therefore, you should try to use the IT equipment with a wide range of operating temperature and humidity. In addition, the relevant operating experience indicates that for the air conditioning system, under the conditions of the other operating conditions unchanged, if the operation temperature of air conditioning is increased by 1℃, it will raise its operation efficiency about 3%.

Second, introduce the technology of natural cooling and airflow organizations.

Due to the cold air from the traditional room air conditioning cannot be 100% sent to the server-side, the efficiency of the most room air conditioning is only about 60%. In order to achieve the energy-saving of air conditioning, on the one hand, working to improve the airflow organizations, designing hot/cold aisle to distribute the equipment in data center, so that the cold air can pass directly to the access in front of server through the vents, and enables the hot air from the back of the server can be directly exhausted without coming across the cold air, so that it saves the energy consumption of cooling. On the other hand, choose a new air conditioning, for example, interline refrigeration air conditioning, which can be placed on both sides of the server cabinet, so that the hot and cold air can directly exchange between the cabinet and the air conditioning refrigeration in shortest cycle path to reach the cabinet (row) level refrigeration. Compared to room-level cooling, the cabinet-level refrigeration is capable of handling higher heat load density, the refrigeration capacity can vary with changes in IT load by modular products, and fan power consumption can be reduced by 50%. In addition, considering the colder climate, large wind, and close to the water, you should select insulation material for the building envelope, and make full use of the natural cold source in the design of the air-conditioning system, which is the key to the energy saving of room air conditioning.

Third, choose efficient UPS, introduce high-voltage DC power supply technology.

The UPS operation load ratio of many data centers is generally about 30%, and the UPS power supply efficiency is 50% to 60%. In response to this situation, the vendors compete in research and development of new technologies to make UPS have a high efficiency even at low load rate. In addition, the high-voltage DC UPS power supply technology in recent years has been gradually spreading, the high voltage DC UPS decreases two AC-DC conversion in the internal structure, energy saving is up to 10% to 20%.

Fourth, adopt green energy-saving LED light source, replace or partially replace the traditional light source.

Fifth, rational planning, conduct development of modular expansion.

In fact, over-planning is also one of the reasons resulting in high energy consumption and low efficiency of data center. Traditional data centers generally adopt one-time design, which not only led to high cost of initial purchase of the UPS and air conditioning equipment, but also increased the cost of energy consumption and services in later period. Users of the data center should take into account the need for future expansion, in accordance with the idea of growth while investment, procurement of the necessary equipment room facilities in section, realizing modular expansion, which will greatly reduce data center room power and cooling loss.

Sixth, intelligent centralized monitoring and management.

Room management of the data center is developing toward the precise direction to conduct real-time detection of cabinet microenvironment and to avoid generating unnecessary power and cooling capacity. Users can understand the real-time changes of current by this software and adjust the size of the outlet in order to achieve the energy saving effect. Users can also conduct real-time monitoring of room facilities, get precise knowledge of the room current, temperature, humidity, control the operation of equipment such as air conditioning and UPS to achieve the target of improving efficiency and saving energy.


Product Recommendation

Green Rack C500
The Green Rack cabinet-level micro data center is designed according to the standard of the data center computer room. The cooling, power distribution, monitoring, wiring, UPS and battery modules are integrated into one or more cabinets to form a cabinet-level micro data center, widely applied in monitoring, medical, broadcasting, communications and financial industries.
More info >
Silicon Cube
Silicon Cube leverages Sugon’s latest technologies in terms of computing, high-speed network, massive storage and liquid cooling.
More info >
Green Pool C2000
The Green Pool cabinet pool-level micro data center integrates cabinets, power distribution, cooling, wiring, and monitoring subsystems. It provides two options: closed cold pool and closed hot pool according to the cold and hot air flow in the closed channel. The density range is from 3 to 10 kW in a single cabinet, suitable for medium and low density data centers.
More info >
Green RackC1000
The GreenRow cabinet is equipped with a micro data center, which integrates cabinet, power distribution, cooling, wiring and monitoring systems. It adopts a fully enclosed design. The interior uses the inter-row air conditioner to cool nearby. The cold and hot air flow channels are isolated in the cabinet, and the heat exchange efficiency is greatly improved. The power density of single cabinet can reach up to 30kW, which perfectly matches the construction needs of medium and high density data centers.
More info >

Dawning Information Industry Co.,Ltd. Sugon Building, No.36 Zhongguancun Software Park, No.8 Dongbeiwang West Road, Haidian District, Beijing 100193

Tel:+86 400-810-0466

Fax:+86 10-56308222

E-mail:international@sugon.com

聯(lián)系我們

售后服務(wù)

嚴(yán)正聲明

主站蜘蛛池模板: 男女做爰高清无遮挡免费视频 日韩精品无码免费一区二区三区 亚洲精品久久片久久久久 制服丝袜av无码专区 国产97人人超碰cao蜜芽prom 浪潮av色综合久久天堂 久久久久人妻精品一区蜜桃网站 亚洲红杏成在人线免费视频 久久久欧美国产精品人妻 亚洲精品福利一区二区三区蜜桃 国产午夜成人无码免费看不卡 好紧好湿太硬了我太爽了视频 国产成人精品999视频 人人玩人人添人人澡免费 av免费无码天堂在线 青青草无码国产亚洲 亚洲老鸭窝一区二区三区 日韩成人免费无码不卡视频 国产片av国语在线观看手机版 亚洲精品成人久久av 日韩精品一区二区三区影院 亚洲精品一区二区三区四区久久 性欧美videofree高清精品 曰欧一片内射vα在线影院 亚洲国产日韩欧美综合a 在线看片免费人成视频电影 特黄做受又硬又粗又大视频小说 制服丝袜av无码专区 亚洲无av码在线中文字幕 久久精品国产99久久无毒不卡 国产偷国产偷亚洲高清app| 精品欧美小视频在线观看| 久久伊人色av天堂九九小黄鸭| 在线观看免费无码专区| 久久不见久久见免费影院视频观看| 免费观看国产女人高潮视频| 婷婷亚洲天堂影院| 成人区精品一区二区不卡av免费 | 丰满少妇被粗大猛烈进人高清| 亚洲人成伊人成综合网中文| 国产精品成人永久在线四虎|